This document is intended to provide proper installation and use of the Yaskawa drive with custom software. This
document is a supplement to the standard drive technical manual. It describes the effects on the drive parameters
and functions with the software installed. Read and understand this document and the standard drive technical
manuals before attempting to install, adjust, operate, inspect or maintain the drive. Observe all cautions and
warnings in this document and the standard drive technical manuals.
Custom software is written to add
functionality to a standard AC drive to enhance or enable use in a specific application. The software is loaded to
the flash ROM area of the control board, and replaces the standard drive software. Custom software can add new
functions, modify standard functions, or even inhibit standard functions. It can be used to modify display text or
parameter names. Custom software is usually loaded to the drive before delivery. The control board and drive
nameplate are assigned unique part numbers and the software is registered, archived, and retrievable.

When seeking support for a drive with custom software, it is imperative to provide the unique part number shown
on the drive nameplate. The software has been flashed to the control board memory and the operation of
parameters, functions, and monitors are different than the standard drive software, as described herein.

1.0 Overview

This custom software is designed for high frequency motor (spindle) applications. The drive’s maximum output
frequency can be set to either 1000Hz or 1500Hz, depending upon C6-11. C6-11 is a factory level parameter
that can be accessed by setting A1-04 = 0616 (Password) and then setting A1-01 = 616 (Access Level). Do not
change any other factory parameters.
Non-applicable drive functions have been deleted in order to optimize
CPU processing time for this software.

1.1 Basic Specifications

Item

Specification

Maximum Output Frequency

1000Hz (1500Hz when C6-11 = 1)

Control Mode

V/f without encoder feedback only (A1-02 = 0)

Drive Duty Rating

Normal Duty 1 only (C6-01 = 1). See section 6.3

Drive Overload

120% for 1 minute only

Drive Current Rating

See section 6.3

Carrier Frequency

10.0kHz maximum and default

Applicable Inverter Models

230V Class, 20P4 – 2090, 480V Class, 40P4 - 4160


2.0 Changes from Standard Product

a. The drive’s output current has been de-rated to allow for a higher carrier frequency.
b. Many of the drive’s standard features have been deleted.

3.0 Limitations

See section1.1.

4.0 Related Parameters and Functions

4.1 New Parameters

Control Mode *1

Paramete

r

Numb

er

Modbu

s

Addre

ss

Parameter Name

Digital Operator

Display

Description

Ran

ge

Default

Cha

nge

Duri

ng Run

V/f

V/f w/ PG

O

pen

Loop

Vec

tor

Flux

Vec

tor

C6-11 22DH

Frequency

Reference Limit

Unbal Det Sel

Sets the upper limit of the
maximum output
frequency (E1-04).

0: 1000Hz
1: 1500Hz

0 ~ 1

0

No F

-

-

-

*1: Access Level (A1-01): Q = “Quick Start”, A = “Advanced”, F = “Factory”.