Yaskawa AI-010 User Manual

Warning, Caution

Advertising
background image

Yaskawa Electric America, Inc – www.drives.com

IG.AFD.50, Page 1 of 5

Date: 05/22/2007, Rev: 07-05

3-15PSI Pressure Transducer Option Card

AI-010

Part Number: AI-010.

Applicability: E7, F7, G7, P7, GPD506/P5, E7L (Electronic Bypass Control).

Introduction:
This pressure transducer option card converts the air pressure (3-15PSI) applied to its on-board sensor to
electrical current, usable by both industrial and commercial air-conditioning systems. It can be used both as reference or
feedback signal generator. In case of feedback signal usage, the signal should be of course inverted by software or
external/system hardware. The card output range (4-20mA) is tunable by software or external/system hardware. The card
generally needs no calibration, as the accuracy is embedded inside its design.

WARNING

HAZARDOUS VOLTAGE CAN CAUSE SEVERE INJURY OR DEATH.

LOCK ALL INCOMING POWER SOURCES IN “OFF” POSITION.


• To prevent physical damage to the Drive or E7L Panel, Read these instructions thoroughly before installing.
• In GPD506/P5 Drives, an internal operator cable connects the front cover to the Drive. Take care when removing the front
cover.
• After installing the option, ensure all screws are tightened and the front cover is securely in place.


Option Kit AI-010 Contents

Item

No

Part Number

Description

Qty

1

5P70-0247

Brass Female to Male Adapter

2

2

None

3/8 inch Flat Washer

1

3

5P70-0246

Brass Hose Barb to Male Adapter

1

4

5P70-0245

1/8 inch PVC (vinyl) tubing

5 Ft

5

UTC000038

Pressure Sensor Card

1

Figure 1. AI-010 Option Kit