Isolated analog input option card ai-040 – Yaskawa AI-040 User Manual

Page 3

Advertising
background image

Yaskawa Electric America, Inc. – www.drives.com

IG.AFD.55, Page 3 of 4

Date: 10/07/05, Rev: 05-10

Isolated Analog Input Option Card

AI-040

Figure 4. AI-040 Block Diagram

Figure 4 shows two possible modes of operation for the AI-040 option board when installed in the drive. These modes are
selected by drive parameter F2-01 (Input Selection). When F2-01 is set to “ 0 “, 3-channel individual mode is selected. In this
mode, the AI-040 option replaces the analog inputs on the drive’s main control board. See Table 3.

When F2-01 is set to “ 1 “, 3-channel addition mode is selected. In this mode, the AI-040 option adds the three channels
together as shown above. This composite signal becomes the primary speed reference when the reference source parameter
is set to “Option PCB” (b1-01 = 3).

Table 3. Adjustment of the Input Signals

(4)

Model

AI-040

Terminal

F7/G7

Control Board

Terminal

GPD 515/G5

Control Board

Terminal

Gain

Parameter

(3)

Bias

Parameter

(3)

TC1 A1

13

H3-02 H3-03

TC2 A2

14

H3-10 H3-11

3-Channel Individual

(1)

TC3 A3

16

H3-06 H3-07

TC1
TC2

3-Channel Addition

(2)

TC3

Speed

Reference

when b1-01=3

Speed

Reference

when b1-01=3

H3-02 H3-03

(1)

When using the 3-Channel Individual Mode,

Channel 1 (TC1) becomes the primary speed reference.
Channel 2 (TC2) can be configured using parameter H3-09.
Channel 3 (TC3) can be configured using parameter H3-05.

(2)

To use the 3-Channel Addition Mode, parameter b1-01 (Reference Source) must be set to “ 3 “ (Option PCB)

Frequency Reference = TC1 + TC2 + TC3 x TC1
10 10

(3)

See Figure 5.

(4)

Warning: If the application requires that reverse motor rotation be prohibited, Parameter b1-04 must be set to “1” so

the motor will stop whenever the polarity of the input signal becomes negative.

Advertising