Heatsink Filter Kit Option
For F7 Configured Drive
Refer to Figure 4 – Duct installation
(5) Retrieve the duct from the heatsink filter kit. The duct is the large sheetmetal piece to which the filter
housings mount.
(6) Orient the duct as shown in Figure 4, so that the (4) holes in the side of the duct will align with the (4) holes
in the side of the enclosure’s mounting leg, and the (2) clinch nuts align with the (2) holes which screws were
removed from.
(7) Slide the duct behind the enclosure such that it surrounds the exposed drive heatsink. It is possible to install
this duct from either the top or the bottom while the enclosure is mounted to a wall.
Slide duct behind enclosure,
covering exposed heatsink.
Can be installed from top or
bottom
Figure 4 – Duct Installation