Electrical installation 2 - 4 – Yaskawa P7 Drives User Manual

Page 4

Advertising
background image

Electrical Installation 2 - 4

2037

R/L1, S/L2, T/L3,

,

1 U/T1,

V/T2, W/T3, R1/L11, S1/L21, T1/L31

M10

154.8 to 197.9

(17.6 to 22.5)

N/A

4/0

(100)

600Vac

UL Approved

vinyl-sheathed

or equivalent

3

M8

77.4 to 95.0

(8.8 to 10.8)

N/A

Application

Dependent

M10

154.8 to 197.9

(17.6 to 22.5)

N/A

2

(38)

r/

l

1,

s

/

l

2

M4

11.4 to 12.3

(1.3 to 1.4)

N/A

16

(1.25)

2045

R/L1, S/L2, T/L3,

,

1, R1/L11, S1/L21, T1/L31

M10

154.8 to 197.9

(17.6 to 22.5)

N/A

300

(150)

U/T1, V/T2, W/T3

250

(125)

3

M8

77.4 to 95.0

(8.8 to 10.8)

N/A

Application

Dependent

M10

154.8 to 197.9

(17.6 to 22.5)

N/A

1

(50)

r/

l

1,

s

/

l

2

M4

11.4 to 12.3

(1.3 to 1.4)

N/A

16

(1.25)

2055

R/L1, S/L2, T/L3,

,

1, U/T1, V/T2, W/T3,

R1/L11, S1/L21, T1/L31

M10

154.8 to 197.9

(17.6 to 22.5)

N/A

1/0 X 2P

(60 X 2P)

3

M8

77.4 to 95.0

(8.8 to 10.8)

N/A

Application

Dependent

M10

154.8 to 197.9

(17.6 to 22.5)

N/A

1/0

(60)

r/

l

1,

s

/

l

2

M4

11.4 to 12.3

(1.3 to 1.4)

N/A

16

(1.25)

2075

R/L1, S/L2, T/L3, R1/L11, S1/L21, T1/L31

M10

154.8 to 197.9

(17.6 to 22.5)

N/A

4/0 X 2P

(100 X 2P)

U/T1, V/T2, W/T3

N/A

3/0 X 2P

(80 X 2P)

, 1

M12

276.2 to 344.8

(31.4 to 39.2)

N/A

3/0 X 2P

(80 X 2P)

3

M8

77.4 to 95.0

(8.8 to 10.8)

N/A

Application

Dependent

M12

276.2 to 344.8

(31.4 to 39.2)

N/A

3/0

(80)

r/

l

1,

s

/

l

2

M4

11.4 to 12.3

(1.3 to 1.4)

N/A

16

(1.25)

2090

R/L1, S/L2, T/L3,

,

1, R1/L11, S1/L21, T1/L31

M12

276.2 to 344.8

(31.4 to 39.2)

N/A

250 X 2P

(125 X 2P)

U/T1, V/T2, W/T3

N/A

4/0 X 2P

(100 X 2P)

3

M8

77.4 to 95.0

(8.8 to 10.8)

N/A

Application

Dependent

M12

276.2 to 344.8

(31.4 to 39.2)

N/A

2/0 X 2P

(70 X 2P)

r/

l

1,

s

/

l

2

M4

11.4 to 12.3

(1.3 to 1.4)

N/A

16

(1.25)

2110

R/L1, S/L2, T/L3,

,

1, R1/L11, S1/L21, T1/L31

M12

276.2 to 344.8

(31.4 to 39.2)

N/A

350 X 2P

(200 X 2P)

U/T1, V/T2, W/T3

N/A

300 X 2P

(150 X 2P)

3

M8

77.4 to 95.0

(8.8 to 10.8)

N/A

Application

Dependent

M12

276.2 to 344.8

(31.4 to 39.2)

N/A

300 X 2P

(150 X 2P)

r/

l

1,

s

/

l

2

M4

11.4 to 12.3

(1.3 to 1.4)

N/A

16

(1.25)

*1 Wire size range provided for Drives using insulated screw-type terminal blocks. All other models require the use of UL listed connectors. Refer to Table 2.3.
*2 Recommended wire sizes are based on the normal duty (ND) current ratings and NEC Article 310 Table 310.16, 75 degree Celsius copper or equivalent.
When sizing wiring based on the heavy duty (HD) current ratings, consult NEC Article 430 and any other applicable codes.

Table 2.1 208-240Vac Wire Sizes and Connector Specifications (Continued)

Drive Model

CIMR-P7U

Terminal Symbol

Terminal

Screws

Clamping

Torque

lb. in.

(N•m)

Possible Wire

Sizes AWG

(mm

2

)

*1

Recommended

Wire Size AWG

(mm

2

)

*2

Wire

Type

Advertising