Cpf error details – Yaskawa Varispeed-656 DC5 Converter User Manual

Page 21

Advertising
background image

VS-656DC5 User’s Manual

19 - 20

CPF Error Details

Error

Display

Error Display

Content

Description

Countermeasures

CPF00

Control Circuit
Error 1 (Opera-
tor Transmis-
sion Error)

• Communication between the controller

and operator not established even though 5
sec. have passed since power ON.

• MPU peripheral element check error

• Re-connect operator and

connector

• Check wiring on control cir-

cuit power source

• Replace controller card

CPF01

Control Circuit
Error 2 (Opera-
tor Transmis-
sion Error)

• After communication has been established

between the controller and the operator
after power ON, a 2 sec. + transmission
error occurred.

• MPU peripheral element check error

• Re-connect operator and

connector

• Check wiring on control cir-

cuit power source

• Replace controller card

CPF02

Base Block
Circuit Fault

Converter Controller Fault

Replace control card

CPF03

EEPROM Fault

CPF04

CPU-Internal
A/D Converter
Fault

CPF05

CPU-External
A/D Converter
Fault

CPF06

Option Con-
nection Error

Option card improperly connected.

Re-insert option card.

CPF07

PWM Timer
Error

Converter Controller Fault

Replace control card

CPF08

DPRAM BCC
Check Error

CPF09

DPRAM Inter-
connection
Diagnostic
Error

CPF10

DPRAM Write
Error

CPF22

Option Device
Code Error

Incompatible option is connected.

Check the connected options.

CPF24

Converter
Card Error

Converter card A/D conversion error.

Replace converter card.

Advertising