Single-Phase Derating
A1000 and P1000 drives are optimized and compatible for use with both three-phase and single-phase input power
supplies. The output to the motor is fixed at three-phase.
Output capacity to the motor is reduced or derated when single-phase input power is used.
Selection of larger models always results in greater output capacity to the motor when the drive supplied with three-phase
input power. Conversely, selection of larger models does not always yield greater output capacity when the drive used
with single-phase input power.
Several factors affect the amount of derated drive output capacity when single-phase input power is supplied to the drive,
such as:
• single-phase input voltage level
• motor voltage rating
• amount of input impedance
The tables in this section assist in model selection by considering factors that affect the amount of derating in single-phase
input power applications.
The Output Capacity-Motor FLA listed in the tables allows for a 120% overload for 60 seconds.
Contact Yaskawa if assistance is needed in selecting drive models for heavy duty/single-phase applications with higher
overload requirements.
Table 4 240 V Single Phase Input (-5% to +10%), 230 V Three Phase Motor
Drive Model
Without Additional Impedance
With Additional Impedance (use either DC type or AC type)
Output Capacity
Single Phase Input Load
Yaskawa Reactor Part Number
Output Capacity
Single Phase Input Load
Motor Power
(HP)
Motor FLA Power (kVA) Current (A)
DC Type
AC Type
Motor Power
(HP)
Motor FLA Power (kVA) Current (A)
2A0004
0.33
1.52
0.99
4.3
URX000043
URX000303
0.5
2.2
0.94
4.1
2A0006
0.5
2.2
1.3
5.7
URX000043
URX000303
0.75
3.2
1.3
5.7
2A0008
0.75
3.2
1.7
7.7
05P00620-0113
URX000307
1
4.2
1.6
7.2
2A0010
0.75
3.2
1.8
7.7
05P00620-0113
URX000311
1
4.2
1.8
7.8
2A0012
1
4.2
2.3
10
URX000048
URX000316
2
7.5
2.9
13
2A0018
2
6.8
4.3
19
05P00620-0120
URX000319
3
9.6
4.3
19
2A0021
2
6.8
4.3
19
05P00620-0120
URX000323
3
9.6
4.4
19
2A0030
2
6.8
4.5
20
05P00620-0120
URX000323
3
9.6
4.4
19
2A0040
3
9.6
6.2
27
05P00620-0124
URX000323
5
15.2
6.7
30
2A0056
5
15.2
9.9
43
URX000059
URX000326
7.5
22
9.6
42
2A0069
5
15.2
10
45
URX000063
URX000332
10
28
13
56
2A0081
10
28
18
79
URX000072
URX000338
15
42
19
84
2A0110
10
28
14
60
DC Reactor
Built-in
Do Not Use
AC Reactor
10
28
14
60
2A0138
15
42
20
87
15
42
20
87
2A0169
20
54
26
114
20
54
26
114
2A0211
20
54
26
116
20
54
26
116
2A0250
25
68
32
143
25
68
32
143
2A0312
30
80
39
170
30
80
39
170
2A0360
40
104
51
224
40
104
51
224
2A0415
50
130
63
275
50
130
63
275