Yaskawa V7 Decel Positioning User Manual

Page 3

Advertising
background image

Date: 12/02/04, Rev: 04-12

Page 3 of 6

TM.V7SW.030



2. Overview

This software is intended for simple positioning applications using limit switches. The software modifies the deceleration
time based on the speed reference so that the creep distance (and therefore the cycle time) is minimized.


3. Related Parameters and Functions

3.1 Parameters

No.

Modbus

Address

Parameter Name

Description

Range

Unit

Default

P-01 0580H

Decel Positioning
Function Selection

0: Decel positioning is disabled.
1: Decel positioning is enabled.

0 ~ 1

-

0

P-02 0581H

Position Speed
Operation Mode
Selection

0: Position speed mode is

disabled. When the drive is
stopped it calculates the
correct decel time based on
the current output frequency.


1: Position speed mode is

enabled. When the position
speed select multi-function
input is closed, the drive
decelerates to position speed
(P-04), using its calculated
decel time. When the run
command is removed, it stops
using its normal decel time.


2: Decel Positioning is enabled –

during Ink Dip decel time is
n022 setting.

0 ~ 2

-

0

P-03

0582H

Decel Time Limit

Sets the upper limit of the
deceleration time during decel
positioning.

0 ~ 300.0

0.1sec

300.0

P-04 0583H Position

Speed

Sets the creep speed for position
speed mode.

0 ~ 400.0

0.01Hz*

2.00

P-05 0584H

Decel
Compensation
Gain

Applies a gain to the calculated
decel rate when the output
frequency at stopping is less than
the decel compensation
frequency (P-06).

1.00 ~ 2.00

-

1.00

P-06 0585H

Decel
Compensation
Frequency

Sets the frequency below which
the decel compensation gain is
applied.

0.01 ~ 400.0

0.01Hz*

50.00

P-07 0586H Ink

Dip

Reference

Sets the frequency reference
used during Ink Dip.

0 ~ 400.0

0.01Hz*

2.00

*For settings greater than 99.99 Hz, the unit is 0.1 Hz.
Note: P-01 ~ P-07 appear after n039 in the programming menu.