Yaskawa V7 Decel Positioning User Manual

Page 4

Advertising
background image

Date: 12/02/04, Rev: 04-12

Page 4 of 6

TM.V7SW.030



3.2 Multi-function input settings (n050 ~ n056)

Setting

Description

100

Position Speed Select

101

Ink Dip Select


3.3 Monitors

No.

Memobus

Address

Monitor Name

Description

Unit

U-50

00D0H

Active Decel Time

Displays the active decel time (either
n020/n022, or the calculated decel rate).

0.01sec*

*For settings greater than 99.99Hz, the unit is 0.1sec.


4. Function Description

Parameter P-01 must be set to 1 or 2 for the Decel Position function to operate. When P-01 = 0, the V7 functions as
standard.

When position speed mode is disabled (P-02 = 0), the V7 functions according to Figure 2. When the run command is
removed, the current frequency reference is sampled and the decel time calculated.

With position speed mode enabled (P-02 = 1), the V7 functions according to Figure 3. When the Position Speed multi-
function input is closed, the current frequency reference is sampled and the decel time calculated. The inverter
decelerates to the P-04 speed using the calculated decel rate. When the run command is removed, the drive will stop
using the normal active decel rate.

When the Ink Dip Select multi-function input is closed, the drive changes direction and runs at the Ink Dip Reference
(P-07). If P-01 = 2, the drive deceleration time during Ink Dip is Deceleration time 2 (n022). If P-01 = 1, the drive
deceleration time during Ink Dip is either the programmed decel time run command is closed) or the calculated decel
positioning time (run command removed). The Ink Dip multi-function input overwrites the Position Speed multi-function
input.

Run

Command

Ink Dip multi-

function input

P-01

setting

Decel Time

OFF OFF 1
OFF OFF 2

tdecel x (Fmax / Fout)

2

x K

OFF

ON

1

tdecel x (Fmax / Fout)

2

x K

OFF ON 2

n022

ON OFF 1
ON OFF 2

N/A

ON ON 1

tdecel

ON ON 2

n022

tdecel = n020/n022 (depending on Accel/Decel Select multi-function input)


Note: If reverse operation is disabled (n006 = 1), the drive has a forward run command and the Ink Dip Select multi-
function input is closed, the drive will will run at the P-07 reference but it will continue to run in the forward direction.