Fast i/o input data, Network communications 3-11 – Yaskawa Profibus-DP Option Card CM061 User Manual
Page 35

Network Communications 3-11
#
Fast I/O Input Data
This area is used to transfer parameter data directly from the drive dual port RAM interface. The following tables detail the functions of the
fast I/O input data (Bytes 0 to 5)
Table 3.14 – 3 Word input/Output Message Fast I/O Input Data
Fast I/O Input Data (Drive -> PROFIBUS-DP Master )
Byte
Function
Bit
Note
0h @
RUN
1h
@ Zero Speed
2h @
Reverse
3h
@ Reset Signal
4h @
Frequency
Agree
5h
@ Drive Ready (Rdy)
6h
@ Minor Fault (Alarm)
0
7h
@ Major Fault
8h
@ OPE Error
9h
@ Fault Restart
Ah
Local/Remote
1 = Remote Operation
Bh
Multi-Function Output 1
1 = Close
Ch
Multi-Function Output 2
1 = Close
Dh
Multi-Function Output 3
1 = Close
Eh
Motor Select
1 = #2 Motor
1
Drive
Status
Fh
@ Zero Servo Complete
2
Frequency Reference MSB
3
Frequency
Reference
Frequency Reference LSB
0.1Hz
scaling is dependent on the setting of parameter o1-03
4
Output Current MSB
5
Output Current
Output Current LSB
Calculated value
Drive Current(Drive Rating/8192)