3.2 External

Settings

The generator run time, temperature, and voltage settings come pre-set

directly from the factory. For the majority of customers, the factory default

settings as shown in Table 3-2 are appropriate. If you need to make changes

to the factory settings, you can do so by rotating the knobs on the front panel

of the AGS controller either clockwise or counterclockwise (see Figure 3-3).

QUIET TIME

PM/AM

setting

CLOCK

AM/PM

setting

START

VOLTS DC

setting

START

TEMP

°F

setting

RUN TIME

HOURS

setting

RUN TIME HOURS: This setting determines the length of time the generator

runs once started. The generator starts because the battery voltage has

fallen to the START VOLTS DC setting for at least two continuous minutes;

or, the temperature around the remote switch has risen to the START TEMP

°F setting. The run time can be set from 1-5 hours. To change this setting,

slowly rotate the knob marked RUN TIME HOURS clockwise to increase

generator run time or counterclockwise to decrease the generator run time.

Adjustable Settings

Factory Default Values

RUN TIME HOURS

2 (Hours)

START TEMP °F

OFF (disabled)

START VOLTS DC

11 (Volts DC)

CLOCK AM/PM

8A (8 AM)

QUIET TIME PM/AM

OFF (disabled)

INPUT DC VOLTAGE

12 Volts (bottom two pins)

GEN TYPE

QD Mode (all 4 switches off)

EXTERNA

L

SETTI

NGS

IN

TERNA

L

SETTINGS

Table 3-2, ME-AGS-S Default Settings

Figure 3-3, External Settings