34

2. Mark off 250mm from the left

hand side of the appliance as

shown in dimension 'A', Fig

3a.

This is the centre line of the fixing

bracket.

3. Draw a line a 100mm from the

front edge of the feet (see Fig.3a)

and remove appliance from its

position. Mark off dimension 'B'

(see Fig.3a) back from this line

on the centre line of the bracket

to locate the

front edge of the

lower bracket. Fix lower bracket

(with two fixing holes) to the floor

then measure the height from

floor level to engagement edge

on back of appliance, dimension

'C' of Fig. 3b.

4. Assemble upper bracket to lower

bracket so that the underside of

bracket is dimension 'C' + 3mm

above floor level. (See Fig. 3b)

Reposition appliance and check

that top bracket engages into

appliance back as shown in Fig.

3b.

The battery

1. The battery is located on the left

hand side of the front plinth.

2. To gain assess to the battery,

open the main oven door and lift

up the battery holder lid.

3. Fit the new battery ensuring (+)

terminal is next to the (+) sign on

the battery. See Fig. 4.

4. Close the

lid of the battery

holder.

Pressure testing

1. The oven injector is used as a

pressure test point.

Remove the oven furniture.

Remove

oven

burner

box

retaining clips (one spring clip

from each side) and remove box

front cover.

Fig.4.