2. Use the function key operations described below to change Trigger Setup settings.

• To change the setting of an item, first use the

f and c cursor keys to move the

highlighting to the item. Next, use the function keys to select the setting you want.

(1) Trigger Source (Source)

• 1(KEY)

b([EXE]) .......... Calculator w key press starts sampling.

c(TRIGER) ...... EA-100 [TRIGGER] key press starts sampling.

• 2(CH1) ........ Channel 1

• 3(CH2) ........ Channel 2

• 4(CH3) ........ Channel 3

• Specifying CH1, CH2, or CH3 as the trigger source displays the specified channel’s

sensor name, trigger threshold initial value, measurement unit, and trigger edge initial
value.

(2) Trigger Threshold (Threshold)

• 1(EDIT) ....... Displays a dialog box for inputting trigger threshold. This option is

available only when CH1, CH2, or CH3 is specified as the trigger
source.

(3) Trigger Edge (Edge)

• 1(Rise) ........ Rising edge triggers sampling

• 2(Fall) .......... Falling edge triggers sampling

3. After all the settings are the way you want, press w to return to the Advanced Setup

menu.