1.4 Control Codes

The command level of this scanner is

ESC/I-D1

. The commands supported

are shown in the table below.

Table 1-3. Control Codes

1.5 Lamp Descriptions

Since this scanner does not have any LED indicator, it shows the various
conditions by turning on/off or blinking the lamp. Conditions indicated by the
lamp are as listed below:



Lamp: On



The scanner is in a normal condition.



Lamp: Blinking



The scanner is turned on before the transportation screw is unlocked.



Communication error



Fatal error except for lamp break has occurred.

NOTE: The lamp goes off after 30 minutes.



Lamp: Off



Power save mode (Command is not received for 10 minutes.)



Power is not supplied.



The lamp has blown out.



The lamp was left blinking for 30 minutes.

Category

Command Name

Code

Execute Command

Request Identity

ESC I

Request Identity 2

ESC i

Request Status

ESC F

Request Extended Status

ESC f

Start Scanning

ESC G

Request Push Button Status

ESC!

Set Data Format

Set Data Format

ESC D i

Set Resolution

ESC R n1 n2

Set Scanning Area

ESC A n1 n2 n3 n4

Set Color

ESC C i

Image Correction

Set Gamma Correction

ESC Z i

Download Gamma Table

ESC z i d[256]

Auxiliary

Set Color Correction Factor

ESC m d[9]

Set Threshold

ESC t i

Set Scanning Mode

ESC g i

Initialize

ESC @

Set Line Counter

ESC d i

Control

Normal Response

ACK

Abnormal Response

NACK

Abort Scanning

CAN

Header

STX