6 error indications – Epson Perfection 610 User Manual

Page 13

Advertising
background image

EPSON Perfection 610

Revision B

Product Description

Error Indications

13

1.6 Error Indications

Refer to Section 1.5 for the error indications.

COMMAND ERROR



Cause:

Undefined command is detected.



Disposition:

The scanner ignores a wrong command and
parameter(s), so it keeps the current settings or
default value effective. The scanner sends
NACK and waits for the next command and
parameter(s).



Indicator:

No effect



Remedy:

Error condition is cleared when the scanner
receives a correct command.

COMMUNICATION ERROR



Cause:

Wrong procedure is detected in the interface
communication.
USB cable was removed during communication.



Disposition:

The scanner stops the ongoing job.



Indicator:

The lamp starts blinking. (The lamp goes off in
30 minutes.)



Remedy:

Turn the scanner off and then back on.
Connect the USB cable again.



Acceptable command:

None

FATAL ERROR



Cause:

The lamp is broken.
The scanner is turned on before the
transportation lock is released.
System breakdown



Disposition:

The scanner stops the ongoing job.



Indicator:

The lamp starts blinking. (The lamp goes off after
30 minutes.)
The lamp does not light up when it has blown.



Remedy:

(After the cause of the error is removed)
Turn the scanner off and then back on.
Connect the USB cable again.
Receiving of ESC@



Acceptable command:

[ESC F, ESC f, ESC @]