Operation – Florabest FTP 400 A1 User Manual

Page 52

Advertising
background image

52

GB

Controls before operational

start-up

• Check that the float switch is

working (see chapter: “Opera-

tion – Automatic mode“).

• Check that the pump is resting

on the pit base

• Check that the pressure line has

been attached properly

• Check the proper status of the

electrical plug socket and make

sure that the plug socket is suf-

ficiently fused (at least 6 A). In-

sert the pump plug into the plug

socket and the pump is ready for

operation.

• Make sure that moisture or water

never come in contact with the

mains connection.There is a risk

of electrocution.

Operation

Mains connection

The submersible water pump acquired by

you is already provided with an grounded

plug. The pump is designed for connection

to an grounded socket with 230V ~50Hz.

Only start to operate the device

after all the above conditions have

been observed.

Switching on and off

1. Insert the plug in the socket. The pump

starts working immediately.

2. To switch off, withdraw the plug from

the socket. The pump stops.

If the water level is too low, the

float switch will automatically

switch off the pump.

Supervise the appliance while it is

in operation in order to be immedi-

ately aware if the automatic cut-out

operates or the pump runs dry, to

limit any damage to a minimum.

Automatic mode

In automatic mode, the float switch auto-

matically switches the pump on or off.

In the case of stationary installation,

check regularly (no less then once

every three months) that the float

switch (10) is working.

The On/Off switch point of the float switch

(6) is infinitely variable:

Loosen the screw in the float switch

height adjustment (5) and move it

to the desired position.

Check the float switch (6).

- It must be positioned so that it

can lift and lower freely. The

switching point heights “On”

and “Off” must be easy to

reach.

Check this by placing the pump

into a vessel filled with water

and lift the float switch (6) care-

fully by hand and then lower it

again. In this case, you can see

whether the pump switches on

and off.

- Also ensure that the separation

distance between the float switch

(6) head and the float switch

height adjustment (5) is not too

Advertising