small. In the case of a separa-

tion distance which is too small,

trouble-free functioning cannot

be guaranteed.

- During the adjustment of the float

switch (6), ensure that the float

switch does not contact the floor

before the pump switches off.

The pump run dry if too long a

float switch cable (

3) is chosen,

particularly if the float switch height

adjustment (

5) is not installed

(see „Assembly“).

Manual mode / flat suction

In manual mode, the pump does not switch

off automatically, as the float switch is

bypassed.

Position the float switch (6) vertical-

ly upward in the float switch height

adjustment (5).

Monitor the pump constantly when

in manual mode. Switch the pump

off immediately (disconnect from

the mains) if no more water is be-

ing pumped. There is a risk of dam-

age if the pump runs dry.

Maintenance and Clean-

ing

Clean and maintain your equipment regu-

larly. This will guarantee its performance

and long durability.

. Ask.our.service.centre.to.car-

ry.out.any.work.that.is.not.

described.in.these.instruc-

tions..Use.only.original.parts..

There.is.a.risk.of.injury!

Pull out the power plug before eve-

ry maintenance operation. There is

a risk of electrocution or of injury

from moving parts.

General cleaning instructions

• In case of transport for utilization in

different locations, the pump must be

cleaned with clear water after every use.

• In case of stationary installation, the

function of the float switch (

6) is

to be checked regularly (at the latest

every three months).

• With a water jet, remove fluff and

fibrous particles which are possibly

present in the pump casing (

12).

• Clean precipitation from the float

switch (

6) with clear water.

• Regularly remove sludge from the pit

base (at the latest every 3 months) and

also clean the shaft walls

• In the case of a long period of non-use,

the pump must be thoroughly cleaned

after the last use and before the new

use, since difficulties in start-up can

arise due to precipitation and residues.

To replace the backflow stop

Replace a defective backflow stop.

1. Unscrew the adapter with the

hose attachment (13) on the

angle adapter (15) and remove

the backflow stop (14a) and seal

(14b).

2. Insert the seal (14b) into the

back flow stop (14a).

3. Set the backflow stop (14) be-

tween the angle adapter (15)

and the adapter with the hose

connection (13) in such a man-