Installation location requirements

For the safe and trouble-free operation of the appliance, the following requirements must be met at the
installation location:

■

The temperature of the water fl owing through it may not exceed 40°C.

■

Use only clean fresh water.

■

Connect the appliance vertically, with the hose connection at the bottom.

■

Minimum operating temperature +5°C.

Connecting the appliance

CAUTION

The irrigation computer may only be connected to a drinking water outlet with a protective appliance
that complies with at least type HD according to EN 1717 (backfl ow preventer with pipe ventilation).

►

Suitable adapters are available from specialist shops.

NOTE

►

The appliance is equipped with a union nut

for water taps with a 33.3 mm thread (G 1").

The adapter

12

is used to connect the appliance to water taps with 26.5 mm thread (G ³⁄₄").

If leaks/leakages occur when using the adapter

12

, wrap some Tefl on sealant tape around the

thread of the water tap.

♦

Insert the sieve

11

into the union nut as shown on the fold-out page.

♦

For 26.5 mm threads (G ³⁄₄"): Screw the adapter

12

to the water tap.

♦

Screw the union nut

onto the thread of the water tap or the adapter.

♦

Screw the connecting piece

13

onto the hose connection

9

. A hose can then be connected to the

connecting piece.

♦

Open the water tap.