Electrolux D77000GF User Manual
Page 41
 
41
CONNECTING TO THE ELECTRICITY SUPPLY
Warning: This appliance must be earthed.
Do not earth this appliance to the gas 
supply piping. 
Connect to 230 - 240V AC supply only.
 
 
•
The electrical connection should be made using a 
double pole isolating switch (cooker socket) with 
at least 3mm contact separation in all poles. The 
cable must have conductors of sufficiently high 
cross-sectional area to prevent overheating and 
deterioration. 
•
We recommend you use a new length of 6mm
2
twin core and earthed cable to ensure your safety.
•
Make connection as shown in Fig 2 by proceeding 
as follows:- 
•
Preform wires to the appropriate shape to suit 
fitting into the mains terminal block. 
•
Strip inner insulation on wires using wire 
strippers. 
•
Twist the bared wires using pliers.
•
Cut bared wires 10mm away from the end of the 
inner insulation. Where uninsulated Earth wires 
are used ensure they are suitably sheathed to 
leave 10mm bare wire to fit into the terminal. 
•
Clamp bare wires into the relevant terminal (Fig. 
2.) and check they are held by tugging each one 
in turn. 
•
Ensure
all
screws are securely tightened.
•
Clamp the mains cable securely ensuring 5mm of 
the outer insuation is inside the terminal block and 
that the wires are not taut but not so slack as to 
cause any fouling. 
•
Connect the remaining end of the mains cable to 
the appliance to the appliance point / junction box. 
•
Place fuse / miniature circuit breaker in circuit and 
switch on at mains. 
When refitting the mains terminal cover, ensure that 
the lower tabs are located inside the bottom edge of 
the aperture, before fixing the two screws into the top 
edge of the mains terminal cover. See Fig.3. Ensure 
that the cover is securely fastened. 
NOTE: HOUSE CIRCUIT 
 
Earth leakage / continuity tests must be carried out 
before the appliance is connected to the mains supply 
and re-checked after fitting. 
 
 
 
 
Fig.2.
Fig.3.
ENSURE THAT THE LINKS ARE FITTED
AS SHOWN IN FIG.2.