Elinca FX 100 User Manual

Page 9

Advertising
background image

8

On/Off

proportional

14

Increase

15

15

Decrease

23035

23101

23033

Modelling lamps and fuse (230V Version)

Unit

Modelling lamp

Code

Socket

Fuse

Code

Style 100FX

100W krypton

23002

E27

2.5AF

19033

Style 400FX

100W krypton

23002

E27

2.5AF

19033

Option:

150W halostar

23035

E27

2.5AF

19033

Option:

200W halogen

23034

GX 6,35

2.5AF

19033

The touch pad (14) controls the modelling lamp on/off and the proportional light.

Select the power with the touch pad (15). The modelling light output (100%) is achieved when

the power value is set to maximum.

Proportional modelling lamp, is set when the position "PROP" is selected (led is illuminated), the

light output is proportional to the selected flash power.

For all types of Style FX compact flash units, use maximum 200 - 250W modelling lamps

Note: lamp socket adapter E27 to GX 6.35, code 23101

This adaptator allows the use of the halogen lamp 200W, GX 6.35 (code 23034) in the Style 100 FX and

400 FX units.

If the modelling lamp does not illuminate, this may be due to the following:

1. The filament is broken after long use *(replace lamp and fuse)

2. The filament is broken after shock *(replace lamp and fuse)

3. An internal component failure, *(return the unit to customer service)

* Action required:

Modelling Light