13

For example, if you have to extend the power cable to the battery or
power buss, attach one end of the fuse holder directly to the battery or
power buss. This will protect both the unit and the power cable in the
event of a short. It uses a 3-amp fuse.

Power connections for the IntelliMap 500C GPS unit.

WARNING:

This product must be independently fused with the en-
closed 3-amp fuse (or equivalent), even if you connect to
a fused accessory or power buss.

If a malfunction happens inside the unit, extensive dam-
age can occur if the enclosed fuse is not used. As with all
electrical devices, this unit could be damaged to a point
that it is not repairable and could even cause harm to the
user when not properly fused.

CAUTION:

Failure to use the enclosed 3-amp fuse will void your warranty! For
a replacement, use a type 3AG 3-amp fuse.

This unit has reverse polarity protection. No damage will occur if the
power wires are reversed. However, the unit will not work until the
wires are attached correctly.

An optional 8-foot, CA-4 external power cable with a cigarette lighter
adapter is available from Eagle.

12 volt

battery

Red wire with

3 amp fuse

To unit

Black wire

Optional power off switch for
saltwater installations