Guidelines for rackmount installation, Attaching brackets and installing in rack, Attaching the rackmount brackets -8 – Enterasys Networks C2K122-24 User Manual

Page 38: Ба б а

Advertising
background image

Rack Mounting the Switch

3-8 Hardware Installation

Guidelines for Rackmount Installation

The installation site must be within reach of the network cabling and meet the 
requirements listed below:

Appropriate grounded power receptacles must be located within 152 cm (5 ft) of the 
location.

A temperature of between 5°C (41°F) and 40°C (104°F) must be maintained at the 
installation site with fluctuations of less than 10°C (18°F) per hour.

Attaching Brackets and Installing in Rack

Proceed as follows to install the switch into a 19‐inch rack:

1.

Attach the rackmount brackets to the switch, as shown in 

Figure 3‐4

, using the eight 

M3 x 6 mm flathead screws shipped with the switch. 

Figure 3-4 Attaching the Rackmount Brackets

2.

With the mounting brackets attached, position the switch between the vertical frame 
members of the 19‐inch rack as shown in 

Figure 3‐5

. Then fasten the switch securely 

to the frame using four mounting screws (user supplied).

Note: To ensure proper ventilation and prevent overheating, leave a minimum clearance
space of 5.1 cm (2.0 in.) at the left, right, and rear of the switch.

Warning: Before rack-mounting the device, ensure that the rack can support it without
compromising stability. Otherwise, personal injury and/or equipment damage may result.

Advertencia: Antes de montar el equipo en el rack, asegurarse que el rack puede
soportar su peso sin comprometer su propia estabilidad, de otra forma, daño personal o
del equipo puede ocurrir.

Warnhinweis: Überzeugen Sie sich vor dem Einbau des Gerätes in das Rack von dessen
Stabilität, ansonsten könnten Personenschäden oder Schäden am Gerät die Folge sein.

1 Rackmount brackets

2 M3 x 6 mm flathead screws

Б

А

Б

А

Console

1

2

23

24

25

26

CPU

UP

RPS

MGR

DOWN

13

14

11

12

25

26

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

C2K122-24

TX RX

TX RX

Advertising