PELLET STOVE

Chapter 5

INSTALLATION AND USE MANUAL

page

44

Maintenance and cleaning

Technical service – Rights reserved MCZ S.p.A. – Reproduction prohibited

EN
G

L

IS

H

On the rear of the stove there is a fuse holding compartment which is

located underneath the supply socket. With a screwdriver open the

cover of the fuse holding compartment, and replace the fuse if

necessary (3.15 AT delayed type). Fig.37
Push the electric plug back in, and press the main switch.
If the problem persists or the fuse blows again, contact an MCZ retailer.

5.3. CHECK OF INTERNAL COMPONENTS

ATTENTION !
Checking of electrical and mechanical components

must be carried out only be qualified personnel with

technical knowledge of combustion and electricity. If

necessary, contact MCZ authorized distributors.


We recommend that an annual maintenance service is carried out,

preferably under a programmed service contract. The essential part of

this service is a visual and functional check on the following

components:

Reduction motor

Smoke expulsion fan

Smoke sensor

Heat-exchanger fan

Ignition sparkplug

Re-settable pellet thermostat

Room temperature sensor

Pressure switch

Main board

Silenced board for heat-exchanger

Overload fuses for panel - main board - silenced board

Wiring

The following is a summary of the checks and/or maintenance tasks

which are indispensable for the correct operation of the stove.

Parts / periods

1 day

2-3 days

30 days

60-90 days

1 year

Burner

Perforated deflector

Ash drawer

Glass

Lower exchanger

Complete exchanger

Smoke ducts

Ash drawer door gasket

Internal parts

Flue pipe

Remote control batteries

Vano

fusibili

Fuse