7

English

Changing Back Tamper position:

The back tamper is by default secured on the right
side of the internal base (Rear view). If you wish to
move it to the left side (rear view), do the following
(Figure 5):

1. Remove tamper screw 1 in order to release the

tamper from position 7.

2. Ensure tamper spring (2) rests over tamper wire

base 4.

3. Ensure plastic tamper bracket (3) rests over

both 2 and 4.

4. Secure tamper screw (1) into (3) over position 6.

Figure 5

Left Side

Tamper

Right Side

Tamper

3

6

1

2

4

7

5

NOTES:

1.

Verify that you hear a "Click" when attaching the tamper spring to the wall.

2.

For pole installation, the tamper can be moved to the bottom right-hand side of the internal base.

Back Tamper Terminal Wiring

If you wish to use the back tamper (recommended) remove the short from the back tamper terminal
block and connect the back tamper wires to the back tamper terminal block.

Back Tamper in use

BACK TAMPER

Back Tamper not used

Short

H1

H1

Configuration Parameters

Via the Agility panel or Configuration Software you can define the following parameter settings of your
detector according to your needs:
1. LEDs operation
On: LEDs enabled (Default: On)
Off: LEDs disabled
2. PIR Sensitivity: High/Normal/Mid/Low (Default: Normal)
3. Mode: Normal/Walk Test (Default: Normal)
For more information refer to the Agility Installer Guide.