Zones Miscellaneous: BUS Zone - WatchOUT
Quick Keys
Parameter
Default
Range
[2][0][3][zz][8] Prox Anti Mask
Enable
Defines the operation of proximity anti masking detection.
[1] Disable [2] Enable
System: Controls
Quick Keys
Parameter
Default
Range
[1][2][57]
Prox AM=Tamper
No
Used to determine the operation of the proximity anti masking detection.
Yes: Proximity anti mask detection will activate the tamper alarm.
No: Proximity anti mask detection will be regarded as a fault.
Note that this parameter is new and replaces the VBR=Tamper parameter
that once used the same quick key sequence.
Note that Proximity AM operates for approximately 2.2 seconds when the
detector is approached in close proximity.
Programming Output Operation Using Proximity Tag
A Programming Output that is defined as “Follow Code” can now also be activated when a
proximity tag is presented to a proximity key reader, a proximity keypad or a G-Tag reader.
PCB Labeling Modification
Some of the labels on the ProSYS PCB will be modified with the following textual changes.
Labels that do not appear in the table below will remain the same.
Note that these modifications a re purely textual and have no impact on the functionality of the
PCB which will remain the same.
New PCB Label
Current PCB Label
Phone SET
Phone B1
Phone A1
Phone LINE
Phone B
Phone A
Terminal COM
Terminal HO
-
Terminal BELL/LS
+ -
Terminal HO SPK
+ -
Terminal BELL
TMP
Terminal TR
-
Terminal BOX
TMP
Terminal LID
TMP
Terminal N.C C N.O
UO1
Terminal OUTPUT 1
TRG C N.O