ProSYS Version 8.xx - Supplementary Instructions

7

BUS Zone Parameters: iWISE DT Grade 2

Quick Keys

Parameter

Default

Range

[2][0][3][zz]
[6][2]

Local (automatic)

Once an hour, the detector automatically checks that the detector’s channels
are functioning properly.

BUS Zone Parameters: iWISE DT Grade 3

Quick Keys

Parameter

Default

Range

[2][0][3][zz][1] LEDS

On

Defines the LEDS operation mode.

[2][0][3][zz][1]
[1] to [2]

LEDS Options

1) Off - Disables the LEDS operation.
2) On – Enables the LEDS operation.

[2][0][3][zz][2] MW (Microwave) Range

Trimmer

Defines the microwave channel range.

[2][0][3][zz][2]
[1] to [7]

MW Range Options

1) Minimum 2) 25% 3) 50% 4) 65% 5) 85% 6) Maximum 7) Trimmer (MW is
defined by the trimmer setting on the PCB)

[2][0][3][zz][3] ACT

No

Defines the Anti-Cloak™ Technology (ACT) operation mode.

[2][0][3][zz][3]
[1] to [2]

ACT Options

1) No - Disables the ACT mode.
2) Yes – Enables the ACT mode.

[2][0][3][zz][4] Automatic Microwave Omit

No

Defines whether the MW channel will be omitted or not while the detector
identifies a fault in the MW channel.

[2][0][3][zz][4]
[1] to [2]

Automatic Microwave Bypass Options

1) No - While detecting a problem in the MW channel it is not omitted. Alarm
condition cannot be established until the MW channel is fixed.
2) Yes - Switches the detector to operate only in PIR mode in case of MW
fault.

[2][0][3][zz][5] Green Line

No

A feature that follows environmental guidelines by avoiding surplus emission.
This feature defines the activation of the microwave channel while the system
is disarmed.

[2][0][3][zz][5]
[1] to [2]

Green Line Options

1) No - Green Line feature is disabled. MW is constantly activated.
2) Yes – Green Line feature is enabled.

[2][0][3][zz][6] Anti-Mask

Enable

Defines the operation of Anti Masking detection.