BUS Zone Parameters: iWISE DT Grade 3

Quick Keys

Parameter

Default

Range

[2][0][3][zz][6]
[1] to [2]

Anti-Mask Options

1) Disable 2) Enable and behaves according to the settings defined in quick
keys [2][0][3][zz][7].

[2][0][3][zz][7] Set/Unset

No

Defines the operation of the anti masking feature while the detector is set or
unset.

[2][0][3][zz][7]
[1]

Set/Unset Options

1) No – When detector is set or unset Anti-mask behaves according to the
settings defined in quick keys [2][0][3][zz][6] above.
2) Yes – when detector is set Anti-mask is disabled. When detector is unset
Anti-mask behaves according to the settings defined in quick keys
[2][0][3][zz][6]

[2][0][3][zz][8] Self Test

Remote

Used to test the detection technologies. In the event of a failed test, a Self
Test Fault is created.

[2][0][3][zz][8]
[1]

Remote (manual)

The remote self test is performed by the system when a user manually
selects the Diagnostics option from the Maintenance menu via the ProSYS
User Functions menu.

[2][0][3][zz][8]
[2]

Local (automatic)

Once an hour, the detector automatically checks that the detector’s channels
are functioning properly.

BUS Zone Parameters: iWISE QUAD Grade 2

Quick Keys

Parameter

Default

Range

[2][0][3][zz]
[1]

LEDS

On

Defines the LEDS operation mode.

[2][0][3][zz]
[1] [1] to [2]

LEDS Options

1) Off - Disables the LEDS operation.
2) On – Enables the LEDS operation.

[2][0][3][zz]
[2]

Sensitivity

Normal

Defines the sensitivity of the detector (PIR).

[2][0][3][zz]
[2] [1]to[4]

Sensitivity Options

1) Low 2) High

[2][0][3][zz]
[3]

Self Test

Remote

Used to test the detection technologies. In the event of a failed test, a Self
Test Trouble is created.

Advertising