RISCO Group ProSYS Version 8.xx User Manual
Page 8

8
ProSYS Version 8.xx - Supplementary Instructions
BUS Zone Parameters: iWISE DT Grade 3
Quick Keys
Parameter
Default
Range
[2][0][3][zz][6]
[1] to [2]
Anti-Mask Options
1) Disable 2) Enable and behaves according to the settings defined in quick
keys [2][0][3][zz][7].
[2][0][3][zz][7] Set/Unset
No
Defines the operation of the anti masking feature while the detector is set or
unset.
[2][0][3][zz][7]
[1]
Set/Unset Options
1) No – When detector is set or unset Anti-mask behaves according to the
settings defined in quick keys [2][0][3][zz][6] above.
2) Yes – when detector is set Anti-mask is disabled. When detector is unset
Anti-mask behaves according to the settings defined in quick keys
[2][0][3][zz][6]
[2][0][3][zz][8] Self Test
Remote
Used to test the detection technologies. In the event of a failed test, a Self
Test Fault is created.
[2][0][3][zz][8]
[1]
Remote (manual)
The remote self test is performed by the system when a user manually
selects the Diagnostics option from the Maintenance menu via the ProSYS
User Functions menu.
[2][0][3][zz][8]
[2]
Local (automatic)
Once an hour, the detector automatically checks that the detector’s channels
are functioning properly.
BUS Zone Parameters: iWISE QUAD Grade 2
Quick Keys
Parameter
Default
Range
[2][0][3][zz]
[1]
LEDS
On
Defines the LEDS operation mode.
[2][0][3][zz]
[1] [1] to [2]
LEDS Options
1) Off - Disables the LEDS operation.
2) On – Enables the LEDS operation.
[2][0][3][zz]
[2]
Sensitivity
Normal
Defines the sensitivity of the detector (PIR).
[2][0][3][zz]
[2] [1]to[4]
Sensitivity Options
1) Low 2) High
[2][0][3][zz]
[3]
Self Test
Remote
Used to test the detection technologies. In the event of a failed test, a Self
Test Trouble is created.