CON FIG C ommands - 3

within one ch aracter time after the last char acter is sen t.

0 = RS-232 (de fault)
1 = RS-422 (transmitter always on)
2 = RS-485

RPC-2350 NOTE: The CAM BASIC statement BIT 128,4, 0 may need to be executed before you
will receive any characters. This command enables the CTS line to the sender.

RELATED:

none

EXAMPLE:

10 CONFIG BAUD 1,7,5,0

This sets CO M1 for the default values.

ERROR:

<

Data negative

>

– all parameters

<

Data out of range

>

– if illegal baud, mode or parity parameter.