Show leakage area Result

Tube configuration is the same as the depressurization

test.

Required by many

states. Also available in

metric units.

Normalized leakage

area is used in many

standards. All common

units are available.

Air Changes per hour

can be shown

directly on the gauge.

Enter volume as shown

below.

Specialized units such

as Effective Leakage

Area are also available.

Pressurization test

Turn the fan around to blow air into the house.

Adjust fan with gauge

Tap [Stop] to turn the fan off.

Connect Speed Control Cable to the fan.

Solid green Status light indicates gauge is connected.

CAUTION: Doors opening during the test will cause

fan speed to increase which will create a pressure pulse

when that door is re-closed, disturbing dust, soot, and

particulates, causing damage. STOP the Fan if a door

opens.

When [Set Speed] or [Set Pressure] is used, the Jog

keys become active on the Home screen. Use the

[JogUp] [JogDown] arrow keys to increase or decrease

the target by 5 Pa or 1%.

Adjust fan speed remotely

When a Result is chosen that requires an

area or volume, [Area] or [Volume] will

be shown on the Home screen.

Tap [Area] or [Volume] to change . The

area and volume can also be changed

from the [Settings] menu.

Page 3 of 4

Page 2 of 4

Use optional WiFi to control the fan remotely. Refer to

“GaugeRemote QuickGuide”.

Tap [Set Speed] [50] [Set] to set speed to 50%.

Tap [Set Pressure] [50] [Set] to get gauge to

control to a pressure of 50 Pa.

Different Results

Tap the [Channel B] key to view a different Result, or

tap [Result to be displayed] on the [Settings] menu.

Tap to return to the Home screen.

Equivalent Leakage Area (EqLA) describes the leakage

area in terms of one large hole in a flat surface.

Tap the [Channel B] key, then

, and select

“EqLA: sq in”

[Channel A] shows the building pressure and

[Channel B] “EqLA” shows the combined size of all

holes in the building.

Leakage area is not a required result, but is a nice way to

visualize the size of the hole in the ducts.