Semi trash pumps - pkx service – Subaru Robin PKX201 User Manual

Page 67

Advertising
background image

Semi Trash Pumps - PKX

Service

- 67 -

25. When reinstalling the smaller adapter plate, make sure

the weep hole faces downward. The weep hole is to

prevent water from entering the engine should the seal

wear

out.

26. The next step after placing the small adapter plate on

the engine is to mount the large adapter plate. Note:

the weep hole position as well, keeping it pointing

downward. Use one bolt to hold on temporarily.

27. Place a small amount of thread locking compound on

the tip of the mounting bolts when reinstalling. Note:

make sure to replace with special supplied bolts and

washer attached. These are special bolts that are

used for sealing pump to engine.

28. Tighten snuggly with hex head (allen wrench)

watching that the adapter plate align correctly with the

back

plate.

Advertising
This manual is related to the following products: