25. When reinstalling the smaller adapter plate, make sure
the weep hole faces downward. The weep hole is to
prevent water from entering the engine should the seal
wear
out.
26. The next step after placing the small adapter plate on
the engine is to mount the large adapter plate. Note:
the weep hole position as well, keeping it pointing
downward. Use one bolt to hold on temporarily.
27. Place a small amount of thread locking compound on
the tip of the mounting bolts when reinstalling. Note:
make sure to replace with special supplied bolts and
washer attached. These are special bolts that are
used for sealing pump to engine.
28. Tighten snuggly with hex head (allen wrench)
watching that the adapter plate align correctly with the
back
plate.