Thermo Pride Spirit Gas TP9C Modulating ECM 97.5% User Manual

Page 16

Advertising
background image

1083292-UIM-A-0114

16

Johnson Controls Unitary Products

FIGURE 23: Thermostat Chart - Two Stage Air Conditioner – Variable Speed Modulating Furnace

C

24 – Volt Common

Y1

First Stage Compressor

Y2

Second Stage

Compressor

G

Fan

*PP32U70124

THERMOSTAT

AUX

Auxiliary Heat

R

24 – Volt Hot

(Heat XFMR)

R

24 – Volt Hot
(Cool XFMR)

C

24 – Volt Common

Y1

First Stage Compressor

Y2

Second Stage

Compressor

G

Fan

*DN22U00124

THERMOSTAT

W2

Second Stage Heat

R

24 – Volt Hot

(Heat XFMR)

R

24 – Volt Hot
(Cool XFMR)

E/W1

Emergency Heat

E/W1

First Stage Heat

TWO STAGE

AIR

CONDITIONER

C

24 – Volt Common

R

24 – Volt Hot

Y1

First Stage Compressor

Y2

Second Stage

Compressor

C

24 – Volt Common

R

24 – Volt Hot

Y1

Single

Stage Compressor

MODULATING

FURNACE CONTROL

G

Fan

MODULATING

FURNACE

Y/Y2

Second or Full

Stage Compressor

DHUM

Dehumidification-

Open on Humidity Rise

W

Modulating Heat

Move HUMIDISTAT

jumper to “YES”

if humidistat is to be used.

ID MODELS

LO COMP

Single Stage

Compressor (OUT)

O

Reversing Valve

Energized in Cool

HI COMP

Second Stage

Compressor (OUT)

External Humidistat

(Optional)

Open on Humidity Rise

TP9C

YP9C

CP9C

LP9C

Thermostat Installer Setup
1-System Type-must
be set to 8-1 Heat/2 Cool
Conventional

Connection of the "C"
terminal, 24-volt common
is optional when used with
batteries

Connection of the "C"
terminal, 24-volt common
is optional when used with
batteries

Thermostat Installer Setup
0170-System Type-must
be set to 10-1 Heat/2 Cool
Multistage Conventional

Thermostat Installer Setup
15-Compressor Protection
must be set to 5

Advertising