Thermo Pride Spirit Gas TP9C Modulating ECM 97.5% User Manual

Page 23

Advertising
background image

1083292-UIM-A-0114

Johnson Controls Unitary Products

23

FIGURE 29: Upflow Configuration

INDUCER ROT

A

TED FOR

LEFT

SIDE VENTING

UPFLOW

AS RECEIVED

INDUCER ROT

A

TED FOR

RIGHT

SIDE VENTING

When drain hose routing changes are required, be sure to cap all un-used openings.

If rerouting hoses - excess length should be cut of

f so that no sagging loops will collect

and hold condensate, which will cause the furnace to not operate.

Shorten

pressure

switch hose

Re-route and

shorten

pressure

switch hose

Shorten

rain

gutter

hose

Move rain

gutter hose

to this position

For 100 & 120K input furnaces, the condensate
drain is plumbed toward the left casing outlet from the factory.

For 060 & 080K input furnaces, the condensate
drain is plumbed toward the right casing outlet from the factory.

Condensate drain may exit cabinet on either side.

1

2

1

2

Advertising