FIGURE 25: Thermostat Chart - Single Stage Heat Pump – Variable Speed Modulating Furnace

C

24 – Volt Common

R

24 – Volt Hot

Y1

First Stage Compressor

O

Reversing Valve

Energized in Cool

L

Malfunction Light

G

Fan

*DP32H70124

THERMOSTAT

W1

Second Stage Aux. Heat

E

Emergency Heat

W2

Third Stage Heat

N/A

*BP21H50124

*BN21H00124

*DP21H40124

*DN21H00124

THERMOSTAT

N/A

*DN22U00124

THERMOSTAT

O

Reversing Valve

Energized in Cool

C

24 – Volt Common

R

24 – Volt Hot

W1/66(out)

Heat

Y

Compressor

DEMAND DEFROST

CONTROL

X/L

Malfunction Light

W

Auxiliary Heat

SINGLE STAGE

HEAT PUMP

Y2

Second Stage Compressor

Step 9 of Thermostat

Installer / Configuration

Menu must be set to

Pump OFF

Step 1 of Thermostat

Installer / Configuration

Menu must be set to

Heat Pump 1

E*B*

E*ZD

E*R*

OD MODELS

*HGD

HP*

*RHS

C

24 – Volt Common

R

24 – Volt Hot

Y1

Single

Stage Compressor

MODULATING

FURNACE CONTROL

G

Fan

MODULATING

FURNACE

Y/Y2

Second or Full

Stage Compressor

DHUM

Dehumidification-

Open on Humidity Rise

W

Modulating Heat

Move HUMIDISTAT

jumper to “YES”

if humidistat is to be used.

ID MODELS

LO COMP

Single Stage

Compressor (OUT)

O

Reversing Valve

Energized in Cool

HI COMP

Second Stage

Compressor (OUT)

External Humidistat

(Optional)

Open on Humidity Rise

TP9C

YP9C

CP9C

LP9C