Choosing the position, Building-in, L• l l’ l’ 6,4 – DE DIETRICH DTI1177X User Manual

Page 4

Advertising
background image

4

EN

• CHOOSING THE POSITION

The distance between the edge of your appliance
and the side and rear walls (or partitions) must be at
least four centimetres (zone A).
Your appliance may be built in without any restric-
tion. Check, however, that the air intake and outlet
are free of obstruction.
The building-in method opposite is recommended
for use above an oven or a built-in appliance.

BUILDING-IN

Follow the diagram above.
Glue the foam seal underneath your appliance, follo-
wing the perimeter of the hole in the worktop, upon
which your appliance will rest. This will ensure a
good seal against the worktop.
Attach the clips to the hob

(depending on the

model).

4 cm

4 cm

4 cm

Entrée d'air

Sortie d'air

4 cm

A

ventilation space

l

L

l’

L’

6,4

Above an oven

MIN 4 mm

Above a cabinet
with a door or drawer

Tip

If your hob is located above your oven, the hob’s thermal safety devices can impede the

simultaneous use of the hob and the oven’s pyrolysis program.

Your hob is equipped with an anti-overheating safety system.

This safety device can trigger, for example, when the hob is installed over an oven that is not suf-

ficiently insulated. If this occurs, a series of small lines appears on the control panel. In such cir-

cumstances we recommend that you increase the hob’s ventilation by creating an opening in the

side of the cabinet, (8 x 5 cm), and/or installing an oven insulation kit available from the after-sales

(Ref . 75X1652)

You can also install your hob above a dishwasher.

In this case, your worktop must be at least 900mm high in order to ensure proper ventilation to

your hob and you could also fit the dishwasher insulation kit that is available from the After-Sales

Service (Ref. 77X7781).

Air outlet

Air intake

1 / INSTALLING YOUR APPLIANCE

Advertising
This manual is related to the following products: