Technical specifications, Characteristics – Amprobe ACD-55HPQ Clamp-Meter User Manual

Page 27

Advertising
background image

ACD-55HPQ

6. TECHNICAL SPECIFICATIONS

6.1. CHARACTERISTICS
Accuracy is indicated as [% of reading + digit number]. It is referred to the following
reference conditions: 23°C ± 5°C with RH <75%.

DC Voltage

Range Resolution Accuracy Input

impedance

1.6 - 599.9V

0.1V

±(1.0% rdg + 3 dgt)

1M

AC Voltage (TRMS)

Accuracy

Range Resolution

40 - 200Hz

200 - 400Hz

Input impedante

1.6 - 599.9V

0.1V

±(1.0% rdg+3 dgt) ±(5.0% rdg + 3 dgt)

1M


Max. Crest factor = 1.5

MAX / MIN / AVG / PEAK AC/DC Voltage

Function Range Resolution Accuracy

Response

time

MAX,MIN,AVG 10 - 599.9V

0.1V

±(5.0% rdg + 10 dgt)

500ms

PEAK

10 - 850V

1V

±(5.0% rdg + 10 dgt)

1ms

AC Current (TRMS)

Accuracy

Range Resolution

40 - 200Hz

200 - 400Hz

Overload protection

0.0 - 399.9A

0.1A

±(1.0% rdg+3 dgt) ±(5.0% rdg + 5 dgt)

600A RMS

Max. Crest factor = 2

MAX / MIN / AVG / PEAK AC Current

Function Range Resolution Accuracy

Response

time

Overload

protection

MAX,MIN,AVG 1.0 - 399.9A

0.1A

±(5.0% rdg + 10 dgt)

500ms 600A

RMS

PEAK

10 - 800A

1A

±(5.0% rdg + 10 dgt)

15ms 600A

RMS

Resistance and Continuity test

Range Resolution Accuracy Overload

protection

0.0 - 499.9

Ω 0.1Ω

500 - 999

1

1000 - 1999

3

±(1.0% rdg + 5 dgt)

600V AC/DC RMS

Instrument emitted a buzzer for R<40

Frequency (with test leads)

Range Resolution Accuracy Overload

protection

40.0 - 399.9Hz

0.1Hz

±(0.5% rdg + 1 dgt)

600V RMS

Voltage range for frequency measure: 0.5 - 600V

Frequency (with jaws)

Range Resolution Accuracy Overload

protection

40.0 - 399.9Hz

0.1Hz

±(0.5% rdg + 1 dgt)

600A RMS

Voltage range for frequency measure: 0.5 - 400V

EN - 23