Specifications display – Amprobe 5XP-A 15XP-A 35XP-A User Manual

Page 19

Advertising
background image

11

12

To replace the fuse:

1. Remove the 2 rear-case screws.

2. Separate the case.

3. Remove and replace the 2 A fuse (15XP-B or 35XP-A)

or 0.315 fuse (5XP-A).

4. Reassemble the meter.

Fuse:
Fast Blow 2 A/1000 V, minimum interrupt rating 30 kA
(6 x 32 mm) (Amprobe® FP200).

Fast Blow 0.315 A/1000 V minimum interrupt rating 30 kA
(6.3 x 32 mm) (Amprobe® FP300)

SPECIFICATIONS

Display:

5XP-A and 15XP-B

:

3 ½ digit liquid crystal display (LCD) with a

maximum reading of 1999.

35XP-A:

3 ¾ digit liquid crystal display (LCD) with a maximum

reading of 3999.

Polarity: Automatic, positive implied, negative polarity
indication.

Overrange:

0o

or

-0o

is displayed.

Battery life:

Approximately 200 hours typical with carbon-

zinc battery. 400 hours with alkaline battery.

Low battery indication: The

symbol is displayed when

the battery voltage drops below the operating level.

Operating environment: 0 °C to 50 °C at <70 % R.H.

Power: Single standard 9 V battery, NEDA 1604, JIS 006P, IEC
6F22.

Dimensions: 155 mm (H) ×72 mm (W) ×32 mm (D)

Weight: Approximately 210 g including battery.