Control signals - reset, Control signals - xfer_active – Avago Technologies LSI53C120 User Manual
Page 41

Electrical Characteristics
3-11
provides the minimum and maximum values for the
LSI53C120 Differential signals.
Tables
and
provide the minimum and maximum values for the
LSI53C120 Control signals.
Table 3.14
Differential Signals - B_SDIR(15-0), B_SDIRP0, B_SDIRP1, B_CD_DIR,
B_IO_DIR, B_MSGDIR, B_REQDIR, B_B_ACKDIR, B_BSYDIR, B_SELDIR,
B_RSTDIR
Symbol
Parameter
Min
Max
Unit
Test Conditions
V
OH
Output high voltage
2.4
V
DD
V
-4 mA
V
OL
Output low voltage
V
SS
0.4
V
4 mA
I
OZ
3-state leakage
-10
10
µ
A
–
Table 3.15
Control Signals - RESET/
Symbol
Parameter
Min
Max
Unit
Test Conditions
V
IH
Input high voltage
3.5
V
DD
+ 0.5
V
–
V
IL
Input low voltage
V
SS
- 0.5
1.5
V
–
I
OZ
3-state leakage
-10
10
µ
A
–
Table 3.16
Control Signals - XFER_ACTIVE
Symbol
Parameter
Min
Max
Unit
Test Conditions
V
OH
Output high voltage
2.4
V
DD
V
16 mA
V
OL
Output low voltage
V
SS
0.4
V
16 mA
I
OZ
3-state leakage
-10
10
µ
A
–