ProSoft Technology MVI71-DNP User Manual
Page 18

MVI71-DNP ♦ PLC Platform
Start Here
DNP 3.0 Master/Slave Communication Module
Page 18 of 172
ProSoft Technology, Inc.
August 23, 2007
Note:
If the list of configured drivers is blank, you must first choose and configure a
driver from the Available Driver Types list. The recommended driver type to choose for
serial communication with the processor is "RS-232 DF1 Devices".
3
Click to select the driver, and then click Configure. This action opens the
Configure Allen-Bradley DF1 Communications Device dialog box.
4
Click the Auto-Configure button. RSLinx will attempt to configure your serial
port to work with the selected driver.
5
When you see the message "Auto Configuration Successful", click the OK
button to dismiss the dialog box.
Note:
If the auto-configuration procedure fails, verify that the cables are connected
correctly between the processor and the serial port on your computer, and then try
again. If you are still unable to auto-configure the port, refer to your RSLinx
documentation for further troubleshooting steps.