Epson SureLab D1070 Professional Minilab Printer User Manual

Page 77

Advertising
background image

SL-D1000 Series User's Guide

Maintenance

77

The

A

roller has a combination of different

cross-sectional shapes. Wipe off the surfaces
that protrude, indicated by

in the

illustration. The places that do not protrude do
not contact the paper when feeding, so they do
not need to be wiped.

3

Leave the A and B feed rollers for a short time so
their surfaces dry, and then install them in the
duplex feeder.

See the following for the installation procedure.

U

“Replacing Feed Rollers” on page 72

Continue to the next section to clean the transfer
rollers.

How to clean the transfer rollers

1

Confirm that the printer’s power is turned off
and the cover of the duplex feeder is open.

2

Use a soft cloth that has been dipped in water
and carefully wrung out to wipe any dirt, such as
paper dust, off of the transfer rollers.

O

Wipe the surface of all 16 rollers shown in
the image.

O

Rotate the metal shafts of the rollers to spin
the rollers to wipe their entire surfaces.

O

Besides paper dust, dirt that is difficult to
check visually, such as the residue of paper
coatings, could be stuck to the surface of the
rollers. Do not just wipe off the paper dust,
carefully wipe the entire circumference of
the rollers. Also, always wipe with a clean
part of the cloth.

c

Important:

Do not wipe the rollers with a dry cloth.

This could scratch the surface of the rollers.

Advertising