17. To attach the vent connections at the fireplace, be sure the 7”

diameter adapter collar has been installed per step 3. Apply

a bead of silicone sealant to the 4” diameter flex connector,

then slide the flex pipe adapter collar into the fireplace flue

collar and secure by installing a minimum of two (2) screws

through the flue collar and into the adapter. See Figure 36.

18. Apply sealant to the 7” diameter adapter collar, slide outer

flex vent over the collar, then secure with a 7” diameter band

clamp. See Figure 36.

19. Once the lower connections are made and the flex pipe is

secured with support bands as required (3 feet minimum be-

tween supports) then the roof flashing can be installed. See

Figure 37.

20. Install the roof flashing, and seal using common construc-

tions practices.

21. An additional storm collar band is provided in kit that may be

used as an attic insulation shield. The collar can be installed

around the flex pipe (or hard pipe) just above the firestop

thimble. This collar will act as a shield to prevent blown in-

sulation from entering the thimble.

22. To complete the vent installation, install the vent termination

cap to the top of the hard vent pipe assembly. Mate up the flue

and outer telescopes with the hard pipe assembly, then secure

by installing a minimum of two (2) sheet metal screws into

the overlapped flanges of the cap and pipe.

23. Figure 38 shows a completed installation with components

identified and other installation information such as heights

and clearance to combustibles.

BAND CLAMP

APPLY HIGH

TEMPERATURE
SEALANT

(WITH GASKET)

ADAPTER COLLAR

7" DIA. INLET

4" DIA. FLUE

ADAPTER
COLLAR

FLUE PIPE

4" DIA. FLEX

7” DIA. FLEX AIR
INTAKE PIPE

Vent Cap

Storm

Minimum

Clearance to

Combustibles

Collar

Exterior

Roof

Roof

Flashing

Support

Roof

Assembly

7"(178mm) Dia.

Must Extend

7"(178mm) Dia.

Hard Pipe

Through Roof

Flashing

1” (25mm)

Flex

Figure 36

Figure 37

DVVK-4FV DIRECT VENT TERMINATION KIT (cont.)