1. To wire Junction Box Receptacle, remove the tab on the side of

the receptacle (hot side) to split receptacle. This will be required

to separate blower and valve circuits.

2. Power for switched and live sides of Duplex Receptacle must

come from the same power source. (One circuit breaker on main

panel must switch all power off.)

3. From the wall box to the fireplace a 3-wire conductor with

ground is recommended, however (2) two-wire conductors

with grounds may be used in place of a 3-wire conductor with

a ground if the black wires from the thermostat and blower

switch are identified.

4. Two wall switches, or a wall switch and thermostat may be used

to activate the two receptacle plugs independently.

The intermittent pilot (120/24 volt system) is ON when the main

burner is ON. When the main burner is OFF the intermittent pilot

is OFF.
The pilot flame should envelop 3/8 to 1/2 inch (10 to 13mm) of

the tip of the flame rod.
To adjust:

1. Remove the pilot adjustment cover screw.

2. Turn the inner adjustment screw clockwise

to

decrease or counterclockwise

to increase pilot

flame. Pilot adjustment is shipped at full flow rate. Turn

the inner adjustment screw clockwise

if the inlet

pressure is too high.

3. Replace the cover screw after the adjustment to prevent gas

leakage.

Label all wires prior to disconnection when servicing controls.

Wiring errors can cause improper and dangerous operation.

Verify proper operation after servicing.

Provided on the intermittent pilot wiring harness are two (2) stripped

and bare wires that are labeled THERMOSTAT. The wires will be

used for attachment of 24 volt thermostat, optional FWS-1 wall

switch or will attach into the receiver on an optional FRBC-1,

FRBTC-1 or FREC-1 remote control.
Installation of Remote Receiver

Place remote receiver on the floor of fireplace behind the louver

as far forward as possible.
Attention: The velcro loop and hook are not necessary in this

installation but can be used to secure remote receiver.

Figure 83

ELECTRICAL CONNECTION (Figure 84)

The DVP Intermittent Pilot Models with optional fan requires 120

VAC electrical hookup to the electrical box (installed).
The appliance, when installed, must be electrically grounded in

accordance with local codes or, in the absence of local codes,

with the National Electrical Code, ANSI/NFPA 70, if an external

electrical source is utilized.

CAUTION: ALL WIRING SHOULD BE DONE BY A QUALI-

FIED ELECTRICIAN AND SHALL BE IN COMPLIANCE

WITH ALL LOCAL, CITY AND STATE BUILDING CODES.

BEFORE MAKING THE ELECTRICAL CONNECTION,

MAKE SURE THAT MAIN POWER SUPPLY IS DISCON-

NECTED. THE APPLIANCE, WHEN INSTALLED, MUST

BE ELECTRICALLY GROUNDED IN ACCORDANCE

WITH LOCAL CODES OR, IN THE ABSENCE OF LO-

CAL CODES, WITH THE NATIONAL ELECTRICAL CODE

ANSI/NFPA 70 (LATEST EDITION).

Figure 84

INTERMITTENT PILOT OPERATING INSTRUCTIONS

INTERMITTENT PILOT WIRING DIAGRAM