Removing the blower, Adjusting the venturies, Replacing the blower – Enviro C-10365 User Manual

Page 20: Initial installation

Advertising
background image

A

DJUSTING

T

HE

V

ENTURIES

:

• There is a separate venturies for each burner, see Figure 29.
• Remove one screw from the cover plate located below

the ash shelf and loosen the other screw (do not

remove) swing the cover plate out of the way and

tighten screw down to hold it in place.

• With along screwdriver rotate spring clips to open or

close the venturies to the desired setting.

The venturies allows the amount of air coming into

the fireplace to be adjusted in order to accommodate

different climates and venting arrangements. Start the

pilot and then the burner. Make sure the pilot flame

is burning normally and none of the burner ports are

plugged. Let the fireplace burn for roughly fifteen

minutes and then examine the flames, compare the

flames to Figure 36.
The ideal flame will be blue at the base and light orange above. The flames should be of medium height. If the

flames look like this, no venturi adjustment is needed. If the flames are fairly short and mostly blue, the fireplace

is getting too much air. Therefore, the venturies should be closed slightly until the correct flames are achieved.

Flames that are very orange, with tall, dark, stringy tips, are not getting enough air. Open the venturi until the

flames clean up. If the venturi is opened, or closed all the way, and the correct flames cannot be attained, turn off

the gas and contact the dealer.

Warning: Incorrect venturi adjustment may lead to improper combustion, which is a safety hazard. Contact the

dealer if there is any concern about the venturi adjustment.

Initial Installation

Gold bar

Screwdriver

Rear log holder

Front log holder Ember tray &

front burner

Venturies

Door

Rear burner

Air shutter cover plate

20

R

EPLACING

T

HE

B

LOWER

:

Figure 28: Blower (Fan) Removal.

1. Turn the unit off and remove the log set.
2. Remove the brick liner.
3. Remove the burner tray assembly by removing the

screw on either side of the tray, between the front and

rear burners. Lift the tray out.

4. Remove the four (4)

5

/

16

” bolts that hold the blower

mounting plate to the back firewall. Use a light

lubricating oil on screws before removal.

5. Carefully pull the blower assembly into the firebox

(see Figure 28) disconnect the blower leads from the

harness and remove blower.

6. To re-install, check mounting plate gasket if damaged

replace with new one and reverse steps 1 through 4.

Refer to “Secondary Installation - Installation of Panel

Set” and “Secondary Installation - Installation of Log

Set and Embers”.

Figure 29: Venturi Adjustment.

Advertising
This manual is related to the following products: