Secondary installation – Enviro C-10365 User Manual

Page 24

Advertising
background image

Secondary Installation

CAUTION: NEVER OPERATE THIS APPLIANCE WITH THE GLASS DOOR REMOVED.

4. Upon the first light up, watch for

ignition to ALL burner ports. If a long

delay is noted: First, wait for the appliance

to cool down.
• Open the front door of the appliance.
• Check to carefully reposition the embers

making sure that burner ports are not

plugged solid or blocked.

Important note: When the unit is turned

on for the first time, It should be turned

onto high without the fan on for the first 4

hours. This will cure the paint, logs, gasket

material and the other products used in

the manufacturing process. It is advisable

to open a window or door, as the unit

will start to smoke and can irritate some

people. After the unit has gone through

the first burn turn the unit off including

the pilot, let the unit get cold then remove

the glass door and clean it with a good gas

fireplace glass cleaner, available at your

local ENVIRO dealer.
See Routine Maintenance And Service on

how to remove door to clean glass.

Figure 35: Log Placement with Embers.

Figure 36: Appliance Burning.

24

Figure 34: Step 4 of Log Placement.