OVERLOUD GEMS
COMP670
METERING
- Meters can be set to display Gain Reduction, Input, Output or Harmonic generation
levels.
LINK
- All
LINK
switches optionally connect equiva-
lent controls present on LEFT/RIGHT or LAT/VERT
channels.
DC THRESHOLD
- This control is a small trimmer inside the compressor unit, to be adjusted with a
screwdriver. It changes the compression curve, from soft-knee to hard-knee.
HARM
- Adjusts the amount of non linear processing, which turns into adding harmonics to enrich
the processed signal.
OUTPUT
- Controls the level of the two channels after the compression. Can be used as a make-up
gain. In LAT/VERT mode it can increase or reduce the stereo image in proportion to the mono
image.
SIDECHAIN FILTER
- Additional high pass
fi
lter on the sidechain which makes the compression less
sensitive to bass frequencies. This is useful to reduce the pumping e
ff
ect if the processed signal
has much bass frequencies.
PARALLEL
- Mixes
DRY
and
WET
signals creating a parallel compression e
ff
ect.
OUTPUT
- Controls the overall output level.
STEREO LINK
- When set in LEFT/RIGHT mode, the compressor works as two independent mono
compressor units. This
PREFERENCE
optionally links both compressors together.
This diagram describes the
COMP670
internal sections and the way they are interconnected.
29
The chain button on the top bar can be used
to turn all links ON or OFF at once.