Elation Professional Elation SIXBAR 1000 IP WMG RGBAW+UV LED Batten Fixture (White Marine Grade Finish) User Manual
Page 11

w w w . e l a t i o n l i g h t i n g . c o m
11
F I X T U R E I N S T A L L A T I O N
F L A M M A B L E M A T E R I A L W A R N I N G
Keep fixture at least 5.0 ft (1.5m) away from any
flammable materials, decorations, pyrotechnics, etc.
E L E C T R I C A L C O N N E C T I O N S
A q u a lifie d e le c tric ia n s h o u ld b e u s e d fo r a ll
e le c tric a l c o n n e c tio n s a n d / o r in s ta lla tio n s .
C A U T I O N S
•
For added protection, mount the fixture in areas outside walking paths, seating areas, or
in areas were unauthorized personnel might reach the fixture.
•
Ambient operating temperature range for this fixture is
5° to 113°F.
(-15° to 45°C)
Do not use the fixture under or above this temperature.
•
Before mounting the fixture to any surface, make sure the installation area can hold a
minimum point load of 10 times the weight of the fixture.
•
Fixture installation must always be secured with a secondary safety attachment, such as
an appropriate safety cable.
•
Never stand directly below the device when mounting, removing or servicing.
•
Ensure ALL connections and end caps are properly sealed with a dielectric grease
(available at most electrical suppliers) to prevent water corrosion and/or electrical short
circuit.
POWER LINKING
Max number of units that can be power linked is
6 units @110V
and
14 units @240V
.
CLAMP MOUNTING
The fixture provides an integrated mounting dual bracket / yoke. Make sure to secure an
appropriately rated clamp to the mounting bracket using M10 screws when mounting this
fixture to truss.