Specifications – Enviro EF THERMO 28 User Manual

Page 5

Advertising
background image

5

Specifications

EF T

HERMO

D

ATA

:

Necessary draught

34.8 Pa (0.348 mbar)

Mass of Appliance

157 Kg

Minimum required load bearing capacity of the floor 247 Kg

Water content

17.3 liters

Exhaust gas temperature at nominal heat output

230°C

Exhaust gas temperature at minimum heat output

120°C

Exhaust mass flow at nominal heat output

7.5 g/s

Exhaust mass flow at minimum heat output

8.0 g/s

Flue pipe diameter

80 mm

Space heating output

to be determined by Lab Testing KW

Water heating output

to be determined by Lab Testing KW

Nominal heating output

25 kW

Heat output range

2.5 kW - 25 kW

Combustion period at Q

N

12 hours

Setting range for the temperature controller

30°C - 75°C

Fuel (type, size, water content)

Wood pellets, 6 mm dia. maximum, <8% W.C.

Hopper capacity

77.75 liters (55 Kg)

Hopper filing opening

440 mm x 320 mm

Auxiliary power requirements

800 W

Test pressure

4.5 bar

Operating pressure

0.5 bar - 2.5 bar

Maximum water pressure

3.0 bar

Maximum water temperature

90°C

Burn Rate

1.0 - 4.5 Kg/hr

Maximum Power Requirement

800 watts

Voltage Rating Range

220-240 volt at 50 Hz

Amperage Rating

3.3 Amp

Table 1

Advertising