Electrical characteristics, Environmental conditions – Epson TM-S1000 User Manual

Page 36

Advertising
background image

36

Electrical Characteristics

Environmental Conditions

Power supply

AC adapter, C

Operating voltage

24 V ± 10%

Current

consumption

Operating

Mean: Approximately 1.0A

Standby

Mean: Approximately 0.2A

Temperature/

humidity

Operating

10 ~ 40°C {50 ~ 104°F}, 20 ~ 80% RH without condensation

(See the operating temperature and humidity range below.)

Storage

(Factory packing)

-20 ~ 60°C {-4 ~ 140°F}, 5 ~ 85% RH without condensation (120

hours or less at -20 {-4°F} or 60°C {140°F})

Maximum

absolute rated

temperature

70°C {158°F} (This temperature must never be exceeded

during operation or storage.)

Humidity (%)

80

55

20

10

27 35 40

Temperature ( )

[%RH]

°C

Advertising