6 mains operation & resulting temperature, Mains operation & resulting temperature – Dynacord IPX5:4 4-Channel Network Power Amplifier (4 x 1250W at 4 Ohms) User Manual

Page 28

Advertising
background image

28

en | Technical data

IPX Series DSP Multichannel Networking Power

Amplifier

2018.04 | 01 | F.01U.330.705

Installation manual

Bosch Security Systems, Inc.

GPIO Control Port

Type

1 x 8-pin Euroblock, male

Ports and Operating Modes

3 x GPIO, switchable Analog In/Digital In/Digital Out

Analog Input Range

0 V to +13 V, 40 kΩ input resistance

Digital Input Limits

ON: < 1.5 V
OFF: > 2.0 V, internal Pull Up (10 kΩ)

Digital Outputs

ON: Output switched to GND, max. 200 mA
OFF: Open Collector (40 kΩ to GND)

Reference Voltage Output

+10 V, max. 200 mA, supervised, short circuit protected

READY/FAULT contact

Galvanic isolated relay, max. 30 VDC/500 mADC

GENERAL

User Interface

Display

Black/white OLED 256 x 64 pixel

Front panel indicators

4 x status LEDs (POWER, STANDBY, FAULT, OMNEO)

Front panel operating elements

3 buttons (UP, ENTER, DOWN)

Rear panel indicators

1 x status LED (STATUS)

Rear panel operating elements

Mains Switch

Power Requirements

100 V to 240 V, 50 Hz to 60 Hz AC

Power Supply Topology

Switching Mode Power Supply with digital controlled Power Factor
Correction

Protections

Audio Limiters, High Temperature, DC, HF, Short Circuit, Back-EMF, Peak
Current Limiters, Inrush Current Limiters, Turn-on Delay, Mains Circuit
Breaker Protection, Mains Over-/Under voltage Protection

Cooling

Front-to-rear, temperature controlled fans, supervised

Ambient Temperature Limits

+5 °C to +40 °C (+40 °F to +105 °F)

IEC Protection Class

Class I (grounded)

Electromagnetical Environment

E1, E2, E3

Color

Black

8.6

Mains operation & resulting temperature

The power drawn from the mains network is converted into output power to feed the
connected loudspeaker systems and into heat. The difference between power consumption
and dispensed power is called power dissipation (Pd). The amount of heat resulting from
power dissipation might remain inside of a rack-shelf and needs to be diverted using
appropriate measures.
For further details refer to the mains operation & resulting temperature tables available at