11 ipl t s series • installation and operation – Extron electronic IPL T S Series User Manual

Page 23

Advertising
background image

2-11

IPL T S Series • Installation and Operation

N

If the Reset button is continuosly held down, every three seconds the LED pulses

(blinks) and puts the unit in a different mode. The Mode 5 LED blinks three
times, the third blink indicating that it is the last mode. The following modes are
separate functions, not a continuation from Mode 1 to Mode 5.

The unit reverts to the factory default
firmware.

Event scripting will not start if

the unit is powered on in this mode. All

user files and settings (drivers,

adjustments, IP settings, etc.) are

maintained.

If you do not want to update
firmware, or you performed a mode 1 reset
by mistake, cycle power to the unit to
return to the firmware version that was
running prior to the mode 1 reset. Use the
0Q SIS command to confirm that the
factory default firmware is no longer
running (look for asterisks following the
version number.)

The connected COM port becomes a
console port to send SIS commands.

Scripting remains on.

Mode 3 turns events on or off.

During

resetting, the Reset LED flashes 2 times if

events are starting, 3 times if events are

stopping.

Mode 4
• Enables ARP capability.

• Sets the IP address back to factory

default (192.168.254.254).

• Sets the subnet back to factory default.

• Sets the default gateway address back

to the factory default.

• Sets port mapping back to factory

default.

• Turns DHCP off.

• Turns events off.

Reset LED flashes 4 times in quick

succession during reset.

Mode 5 performs a complete reset to
factory defaults (except the firmware).
• Does everything mode 4 does.

• Resets almost all the real time

adjustments: all audio settings, limit

initial power up volume, power

up/down delay, auto power down, and

misc. options. This does not affect an

optional MLS switcher, however.

• Clears driver-port associations and port

configurations (IR/RS-232).

• Removes button configurations.

• Resets all IP options.

• Removes scheduling settings.

• Removes/clears all files from switcher.

The Reset LED flashes 4 times in quick

succession during the reset.

Reset Mode Comparison/Summary

Mode Activation

Result

Purpose/Notes

1

Hold down the recessed

Reset button while applying

power to the IPL T S unit.

After a mode 1 reset

is performed, update the
unit’s firmware to the latest
version. Do not operate the
unit’s firmware version that
results from the mode 1
reset. If you want to use the
factory default firmware,
you must upload that
version again.

2

Press and release the Reset

button. Within 2 seconds

type +++ on the keyboard.

N

If the three “+’s”

(+++) are not enetered in
the 2-second time frame, the
COM port becomes a
control port only.

3

Hold down the Reset button

for about 3 sec. until the

Reset LED blinks once, then

press Reset momentarily

(<1 sec.) within 1 second.

4

Hold down the Reset button

for about 6 sec. until the

Reset LED has blinked

twice (once at 3 sec., again

at 6 sec.). Then press Reset

momentarily (for <1 sec.)

within 1 second.

5

Hold down the Reset button

for about 9 sec. until the

Reset LED has blinked three

times (once at 3 sec., again

at 6 sec., again at 9 sec.).

Then press Reset

momentarily (for <1 sec.)

within 1 second.

Use mode 1 to revert

to the factory default

firmware version if

incompatibility issues

arise with

user-loaded firmware.

Mode 2 enables the

SIS console port

Mode 3 is useful for

troubleshooting.

Mode 4 enables you

to set IP address

information using

ARP and the MAC

address.

Mode 5 is useful if

you want to start over

with configuration

and uploading, and

also to replace events.

Advertising