Copyright information, Password information, Copyright information -4 password information -4 – Extron electronic IPL T S Series User Manual

Page 44: Communication and control, cont’d

Advertising
background image

Communication and Control, cont’d

IPL T S Series • Communication and Control

4-4

X3$

= Daylight saving time (DST) is a 1-hour offset (for the USA only) that begins on the first Sunday

of April at 2 am and ends on the last Sunday of October. For example, time in California is
GMT -8:00 from April to October and GMT -7:00 from November to March. DST should be
turned off in Hawaii, American Samoa, Guam, Puerto Rico, the Virgin Islands, the eastern
time zone portion of the state of Indiana, and the state of Arizona (excluding the Navajo
Nation). 0 = off/ignore; 1 = on

X3%

= Event number: range = 0–99 (max.)

X3^

= Event buffer: 0 = receive; 1 = user (absolute); 2 = user (relative); 3 = NVRAM

X3&

= Memory location: range = 0–max. BufferSize

X3*

= Event data size: b = bit; B = byte (8 bit); S = short (16 bit); L = long (32 bit)

N

This parameter is case sensitive.

X3(

= Event data to write

X4!

= Reading password: responds as empty if no password is set, and 4 asterisks (****) if password

exists.

X4$

= Number of bytes to read: range = 1–127 (max.)

X4%

= E-mail event number: range = 1–48 (max.)

X4^

= E-mail recipient address

X4&

= Name of e-mail file to be sent.

N

E-mail files must have the file extension .eml.

X4(

= Default name: a combination of the model-name and the last 3 pairs of the MAC address (e.g.,

IPL-T-S2-00-02-3D)

X5)

= Redirect: 0 = no redirect; 1–n = redirect serial port from the specified port to allow for a

transparent pass-through mode

X5@

= Connection’s security level: 0 = not logged in; 1 = user; 2 = administrator

X5#

= Timeout for data pass-through mode, after which event data can be inserted into the transmit

buffer.

X5$

= ASCII digit(s) representing numeric value of data element read from event buffer. (Leading

zeros are suppressed.)

X6$

= Time in seconds to keep sending the broadcast message

(0–255, default = 10)

X6(

= The number of seconds before timeout on IP connections: (min. = 1; max. = 65000;

default= 30 = 300 seconds). If no data is received during the timeout period, the Ethernet

connection is closed. Each step = 10 seconds. When connected via RS-232, only the global

timeout commands apply. Current returns E13. The response is returned with leading

zeros.

N

X6(

is applicable to Ethernet only.

X7)

= Number (as optional parameter) inserted into an e-mail message if the .eml file has an

embedded ESC CR command with no parameters.

X7!

= Hardware (MAC) address: the four most significant hex nibbles converted into a single 16-bit

decimal number.

X7@

= Hardware (MAC) address: the eight least significant hex nibbles converted into single 32-bit

decimal number.

N

This could be as large as 10 digits.

Copyright information

]

© COPYRIGHT 2006, EXTRON ELECTRONICS IPL T Sx, Vx.xx

]

Mon, 17 Feb 2006 11:27:33

]

The copyright message is displayed upon connecting to the IP Link

®

product via

TCP/IP or Telnet. Sx is the model and Vx.xx is the firmware version number. The

current date and time is displayed. This is followed by a password prompt.

Password information

The “

]

Password:” prompt requires a password (administrator level or user level)

followed by a carriage return. The prompt is repeated if the correct password is not

entered.
If the correct password is entered, the unit responds with “

]

Login Administrator

]

” or “

]

Login User

]

”, depending on the password entered. If the passwords

Advertising